Mosaic MZERO is an economical safety controller with 16 safe inputs, four safe
OSSD outputs and four reset/EDM inputs that can monitor all safety functions of a machine or system.
The Mosaic MZERO is used as a standalone safety PLC and is not expandable.
High diagnostics via status outputs!
With the aid of the four status outputs, up to 32 pieces of information can be transmitted to the higher-level control system.
control system. Software gateway for Siemens TIA, Codesys are available on our homepage.
The project report contains the current values for PFH, DCavg and MTTFd according to EN 13849-1 and EN 62061.
– 16 safety inputs
– 4 inputs for start/restart interlock, EDM or devices with one input
– 4 pairs of OSSD safety outputs (PNP 400 mA)
– 4 status outputs SIL 1/PL c (PNP 100 mA)
– 4 test outputs
– 64 logical operators